ATLANTIS LAND - UPS ATLANTIS A03-OP3002P-RC 3000VA/2700W Rack 2U Doppia conv.-Interf.EPO-6 Batt. 12V/9A -Slot x sk SNMP (sost.A03-OP3001-RC)(A03-OP3002P-RC)

ATLANTIS LAND - UPS ATLANTIS A03-OP3002P-RC 3000VA/2700W Rack 2U Doppia conv.-Interf.EPO-6 Batt. 12V/9A -Slot x sk SNMP (sost.A03-OP3001-RC) (A03-OP3002P-RC)

Codice 3Plus: ATL0564
Codice EAN: 8026974022550
Codice Produttore: A03-OP3002P-RC

Power Rating (VA): 3000
Power Rating (W): 2700

Input (Low Line Transfer):
- 80VAC-300VAC (load <=30%±5%)
- 140VAC-300VAC (load <=60%±5%)
- 160VAC-300VAC (load <=80%±5%)
- 190VAC-300VAC (load <=100%±5%)
Frequency Range: 40Hz to 70Hz
Power Factor: >0,99 (Normal Voltage)

Output
- Voltage: 208/220/230/240VAC
- AC Voltage Regulation: ±1%
- Frequency Range: 50Hz (±0.5%) or 60Hz (±0.5%)
- Waveform: Pure SineWave
- Crest Ratio: 3:1 (Max)
- Harmonic Distortion: <3% THD (liner Load) | <5% THD (Non liner Load)

Transfer:
- AC->Battery: Zero
- INV->ByPass: Less than 4ms (typical)
WaveForm (Batt. Mode): Pure Sinewave

Efficiency:
- AC Mode = 91%
- Battery = 88%
- ECO = 97%

Battery
- Voltage: 72VDC
- Capacity: 12V/9.0Ah
- Quantity: 6
- Recharge Time: 4 hours to (90%)
- Type: Sealed Maintenance Free Lead Acid VRLA Type
- Design: Easy-swappable battery design
- Charging Voltage: 82,1VDC ±1%
- Charging I: 1.5A Max

Indicators LCD Display
- UPS status | Load level | Battery level | Input/Output/battery info | Discharge time and Fault indicators

Backup Times:
- 2700w up to 3:20m
- 2025w up to 5:20m
- 1350w up to 11m
- 675w up to 25m

Protection:
- 105% < Overload AC <110% Overload Warning UPS transfers to ByPass after 10 minutes
- 110% < Overload AC <130% Overload Warning UPS transfers to ByPass after 1 minutes
- Overload AC >130% Overload Warning UPS transfers to ByPass after 3 seconds
- 105% < Overload Battery <110% Overload Warning UPS shut down after 10 minutes
- 110% < Overload Battery <130% Overload Warning UPS shut down after 1 minute
- Overload AC >130% Overload Warning shut down after 3 seconds
- 110% < ByPass <120% Overload Warning UPS shut down after 30 minutes
- 120% < ByPass <130% Overload Warning UPS shut down after 10 minutes
- ByPass >130% Overload Warning UPS shut down after 1 minute
- Overload Inverter (>100%)
- Short Circuit INV: Electric Circuit
- Short Circuit AC: ICB & Electric Circuit
- Battery Over-drain Two stages: Controlled Battery Low Warning & Cut Off
- High Surge Level Immunity (>7KV)

Advanced:
- Fan detect protection and Fan speed control
- Programmable Outlets (4) (Turn ON/Off Delay and Turn Off Threshold)
- ECO mode

Connections
- Output 8xIEC 320 C13 (Battery Power Supplied) + 1xIEC 320 C19
- RS232 and USB (HID)
- Intelligent Slot for SNMP Card
- EPO / ROO
- Battery Bank Connection

Dimensions (WxHxD): 438 x 88 x 610 mm
Net Weight 27,60 Kg (with Battery)
Temperature: 0°-40° C
Humidity: 20-90% (non-condensing)