ATLANTIS LAND - UPS ATLANTIS A03-OP10002P-RC 10000VA/9000W Rack 6U  (3+3) Doppia conv.-Interf.EPO-16 Batt. 12V/9A -Slot x sk SNMP(A03-OP10002P-RC)

ATLANTIS LAND - UPS ATLANTIS A03-OP10002P-RC 10000VA/9000W Rack 6U (3+3) Doppia conv.-Interf.EPO-16 Batt. 12V/9A -Slot x sk SNMP (A03-OP10002P-RC)

Codice 3Plus: ATL0592
Codice EAN: 8026974022833
Codice Produttore: A03-OP10002P-RC

Power Rating (VA): 10000
Power Rating (W): 9000

Input (Low Line Transfer):
- 80VAC-300VAC (load <=30%±5%)
- 140VAC-300VAC (load <=60%±5%)
- 160VAC-300VAC (load <=80%±5%)
- 190VAC-300VAC (load <=100%±5%)
Frequency Range: 45-55Hz / 54-66Hz
Power Factor: >0,99 (Normal Voltage)

Output
- Voltage: 208/220/230/240VAC
- AC Voltage Regulation: ±1%
- Frequency Range: 50Hz (±0.5%) or 60Hz (±0.5%)
- Waveform: Pure SineWave
- Crest Ratio: 3:1 (Max)
- Harmonic Distortion: <2% THD (liner Load) | <5% THD (Non liner Load)

Transfer:
- AC->Battery: Zero
- INV->ByPass: Less than 4ms (typical)
WaveForm (Batt. Mode): Pure Sinewave

Efficiency:
- AC Mode = 92%
- Battery = 90%
- ECO = 96%

Battery
- Voltage: 192VDC
- Capacity: 12V/9.0Ah
- Quantity: 16
- Recharge Time: 6 hours to (90%)
- Type: Sealed Maintenance Free Lead Acid VRLA Type
- Design: Easy-swappable battery design
- Charging Voltage: 218.4 VDC ±1%
- Charging I: 1.0A Max

Indicators LCD Display
- UPS status | Load level | Battery level | Input/Output/battery info | Discharge time and Fault indicators

Backup Times:
- 2700w up to 3:20m
- 2025w up to 5:20m
- 1350w up to 11m
- 675w up to 25m

Protection:
- 105%< Overload AC <110% Overload Warning UPS transfers to ByPass after 10 minutes
- 110%< Overload AC <130% Overload Warning UPS transfers to ByPass after 1 minutes
- Overload AC >130% Overload Warning UPS transfers to ByPass after 3 seconds 
- 105%< Overload Battery <110% Overload Warning UPS shut down after 10 minutes
- 110%< Overload Battery <130% Overload Warning UPS shut down after 1 minute
- Overload AC >130% Overload Warning shut down after 3 seconds 
- 110%< ByPass <120% Overload Warning UPS shut down after 30 minutes
- 120%< ByPass <130% Overload Warning UPS shut down after 10 minutes
- ByPass >130%  Overload Warning UPS shut down after 1 minute
- Overload Inverter (>100%)
- Short Circuit INV: Electric Circuit
- Short Circuit AC: ICB & Electric Circuit
- Battery Over-drain Two stages: Controlled Battery Low Warning & Cut Off
- High Surge Level Immunity (>7KV)

Advanced:
- Fan detect protection and Fan speed control
- ECO mode

Connections
- Terminal Block
- RS232 and USB(HID)
- Intelligent Slot for SNMP Card (A03-SNMP2-IN)
- EPO/ROO
- Battery Box Connection

Dimensions (WxHxD):
- Ups: 438 x 131 (3U) x 480 mm
- Battery Pack: 438 x 131 (3U) x 680 mm

Weight: 70,0 Kg
Noise Level: Less then 55 dBA @ 1.0 meter (battery full charged, without buzzer)
Temperature: 0°-40° C
Humidity: 20-90% (non-condensing)